Now showing items 1-19 of 19
Abstract: | This paper describes the fabrication of an ion-selective electrode in which a polymeric Schiff base complex of cobalt(II) is used as the ionophore.The main advantage of the electrode is that it is mechanically stable upto 3 months..The electrode shows a linear response in the range of 2.5 × 10-5-0.5 × 10-1 mol dm-3. The response time of the electrode is 30 s.The pH range at which the electrode works is 3.8 to 6.8. The electrode was found to be selective towards chloride ion in the presence of ions like Na+, Ca2+, Mn2+, ,Fe3+, Co2+, Ni2+, Cu2+, Zn2+, CH3COO-, NO3-, SO42- ,Br- and NO2-. |
URI: | http://dyuthi.cusat.ac.in/xmlui/purl/1928 |
Files | Size |
---|---|
Girish Kumar,A chloride ion....pdf | (123.8Kb) |
Abstract: | This paper reports the synthesis of a series of six new polystyrene anchored metal complexes of Co(II), Fe(III), Ni(II), Cu(II), Zn(II), and dioxouanium(VI) using the polystyrene anchored Schiff base of 2-nitrobenzaldehyde and the corresponding metal salts. The metal salts used were anhydrous FeCl3, CoCl2 Æ 6H2O, Ni(CH3COO)2 Æ 4H2O, Cu(CH3- COO)2 Æ H2O, Zn(CH3COO)2 Æ 2H2O, and UO2(CH3COO) Æ 2H2O. Physico chemical characterizations have been made from diffuse reflectance and vibrational spectra, elemental analysis, magnetic measurements, and TG studies. The elemental analysis suggest a 1:2 metal:ligand ratio when the complexation has carried out at 70 C for about 12 h reflux. The ligand is monodentate and coordinates through the azomethine nitrogen. The Fe(III), Co(II), Ni(II), and Cu(II) complexes are all paramagnetic whereas Zn(II) and U(VI) are diamagnetic. Zn(II) is assigned a tetrahedral structure, Cu(II) and Co(II) are assigned a square planar structure and Fe(III), Ni(II), and U(VI) are all assigned an octahedral structure. The polystyrene anchored ligand has been developed as an excellent reagent for the removal of Cu(II). Optimum conditions have been developed for the removal of metal ion from solutions by studying the effect of change of concentration of metal ion, ligand, effect of pH, time of reflux, and interference effect of other ions. It was found that within a span of 20 min it is possible to remove 90% of the metal ion from a 30 ppm metal ion solution in the pH range 4–5.5. |
URI: | http://dyuthi.cusat.ac.in/purl/518 |
Files | Size |
---|---|
REACT2135.pdf | (271.9Kb) |
Abstract: | Dipyrromethene-Cu(II) derivatives possessing two dodecane alkyl chains have been used for the modification of gold electrodes. Electroactive host molecules have been incorporated into a lipophilic dodecanethiol SAM deposited onto gold electrodes through hydrophobic and van der Waals interactions (embedment technique). The presence of dipyrromethene-Cu(II) redox centers on the electrode surface was proved by cyclic voltammetry and Osteryoung square-wave voltammetry. The Au electrodes incorporating redox active Cu(II)-dipyrromethene SAMs were used for the direct voltammetric determination of paracetamol in human plasma. |
URI: | http://dyuthi.cusat.ac.in/xmlui/purl/1990 |
Files | Size |
---|---|
Electroactive Dipyrromethene....pdf | (533.7Kb) |
Abstract: | A metalloporphyrin incorporated carbon paste sensor has been developed for the determination of metronidazole benzoate (MTZB). Zn(II) complex of 5,10,15,20-tetrakis (3-methoxy-4-hydroxy phenyl) porphyrin (TMHPP) was used as the active material. The MTZB gave a well-defined reduction peak at - 0.713V in 0.1 mol l -1 phosphate buffer solution of pH around 7. Compared with bare carbon paste electrode (CPE), the TMHPP Zn(II) modified electrode significantly enhanced the reduction peak current of MTZB as well as lowered its reduction potential. Under optimum conditions the reduction peak current was proportional to MTZB concentration over the range 1×10-3 mol1-1 to 1×10-5mol1-1. The detection limit was found to be 4.36×10-6mol1-1 . This sensor has been successfully applied for the determination of MTZB in pharmaceutical formulations and urine samples. |
URI: | http://dyuthi.cusat.ac.in/xmlui/purl/1991 |
Files | Size |
---|---|
Electrochemical reduction and voltammetric....pdf | (460.0Kb) |
Abstract: | A differential pulse voltammetric sensor for the determination of tamsulosin hydrochloride (TAM) using multiwalled carbon nanotubes (MWNTs)–Nafion-modified glassy carbon electrode (GCE) has been developed. MWNTs were dispersed in water with the help of Nafion and were used to modify the surface of GCE via solvent evaporation. At MWNT-modified electrode, TAM gave a well-defined oxidation peak at a potential of 1084 mV in 0.1 M acetate buffer solution of pH 5. Compared to the bare electrode, the peak current of TAM showed a marked increase and the peak potential showed a negative deviation. The determination conditions, such as the amount of MWNT–Nafion suspension, pH of the supporting electrolyte and scan rate, were optimised. Under optimum conditions, the oxidation peak current was proportional to the concentration of TAM in the range 1 × 1023 M–3 × 1027 M with a detection limit of 9.8 × 1028 M. The developed sensor showed good stability, selectivity and was successfully used for the determination of TAM in pharmaceutical formulations and urine samples |
Description: | Micro & Nano Letters, 2011, Vol. 6, Iss. 10, pp. 867–870 |
URI: | http://dyuthi.cusat.ac.in/purl/4708 |
Files | Size |
---|---|
Electrochemical ... d glassy carbon sensor.pdf | (228.3Kb) |
Abstract: | In this communication, we discuss the details of fabricating an off-line fibre optic sensor (FOS) based on evanescent wave absorption for detecting trace amounts of Fe3+ in water. Two types of FOS are developed; one type uses the unclad portion of a multimode silica fibre as the sensing region whereas the other employs the microbent portion of a multimode plastic fibre as the sensing region. Sensing is performed by measuring the absorption of the evanescent wave in a reagent medium surrounding the sensing region. To evaluate the relative merits of the two types of FOS in Fe3+ sensing, a comparative study of the sensors is made, which reveals the superiority of the latter in many respects, such as smaller sensing length, use of a double detection scheme (for detecting both core and cladding modes) and higher sensitivity of cladding mode detection at an intermediate range of concentration along with the added advantage that plastic fibres are inexpensive. A detection limit of 1 ppb is observed in both types of fibre and the range of detection can be as large as 1 ppb–50 ppm. All the measurements are carried out using a LabVIEW set-up. |
URI: | http://dyuthi.cusat.ac.in/purl/603 |
Files | Size |
---|---|
e30622.pdf | (176.4Kb) |
Abstract: | The fabrication and analytical applications of two types of potentiometric sensors for the determination of ketoconazole (KET) are described. The sensors are based on the use of KET-molybdophosphoric acid (MPA) ion pair as electroactive material. The fabricated sensors include both polymer membrane and carbon paste electrodes. Both sensors showed a linear, stable and near Nernstian slope of 57.8mV=decade and 55.2mV=decade for PVC membrane and carbon paste sensors respectively over a relatively wide range of KET concentration (1×10-2-5×10-5 and 1×10-2-1×10-6). The sensors showed a fast response time of <30 sec and <45 sec. A useful pH range of 3–6 was obtained for both types of sensors. A detection limit of 2.96 10 5M was obtained for PVC membrane sensor and 6.91 10 6M was obtained for carbon paste sensor. The proposed sensors proved to have a good selectivity for KET with respect to a large number of ions. The proposed sensors were successfully applied for the determination of KET in pharmaceutical formulations. The results obtained are in good agreement with the values obtained by the standard method. |
URI: | http://dyuthi.cusat.ac.in/xmlui/purl/1989 |
Files | Size |
---|---|
Fabrication of potentiometric....pdf | (210.2Kb) |
Abstract: | Two simple and sensitive spectrophotometric methods (A and B)in the visible region have been developed for the determination of nimesulide in bulk and in dosage forms.Method A is based on the reaction of reduced nimesulide with nitrous acid followed by its coupling with phloroglucinol to yield an yellow colored azo dye with an absorption maximum of 400 nm and method B is based on the reaction of reduced nimesulide with p-dimethylamino benzaldehyde(PDAB) to form an yellow colored chromogen wiht an absorption maximum of 415 nm.When pharmaceutical preparations (Tablets and suspension) were analysed, the results obtained by the proposed methods are in good agreement with the labelled amounts and are comparable with the results obtained by a reported method.recovery in both the method is 98-101 %. |
URI: | http://dyuthi.cusat.ac.in/xmlui/purl/1926 |
Files | Size |
---|---|
Girish Kumar.pdf | (238.5Kb) |
Abstract: | A novel electrochemical sensor has been developed for the determination of nimesulide. The sensor is based on the NIM- molybdophosphoric acid (MPA) as the electroactive material in PVC matrix in presence of bis(2-ethyl hexyl) phthalate (BEP) as a plasticizer. The sensor showed a fast, stable, near Nernstian response for 1 × 10-2 –1 × 10-6 M NIM over the pH range 5 – 8 with a slope 55.6 ±0.5m V/decade and the response time is < 45 s. Selectivity coefficient data for some common ions show negligible interferences. The sensor was successfully applied for the determination of NIM in tablet and the results obtained are in good agreement with those obtained by the official method. |
URI: | http://dyuthi.cusat.ac.in/purl/517 |
Files | Size |
---|---|
PEA%2025%203%202007%20375-381.pdf | (185.5Kb) |
Abstract: | The fabrication and electrochemical response characteristics of two novel potentiometric sensors for the selective determination of domperidone (DOM) are described. The two fabricated sensors incorporate DOM–PTA (phosphotungstic acid) ion pair as the electroactive material. The sensors include a PVC membrane sensor and a carbon paste sensor. The sensors showed a linear, stable, and near Nernstian slope of 56.5 and 57.8 mV/decade for PVC membrane and carbon paste sensors, respectively over a relatively wide range of DOM concentration (1.0 9 10-1–1.0 9 10-5 and 1.0 9 10-1–3.55 9 10-6 M). The response time of DOM–PTA membrane sensor was less than 25 s and that in the case of carbon paste sensor was less than 20 s.Auseful pH range of 4–6 was obtained for both types of sensors. A detection limit of 7.36 9 10-5 M was obtained for PVC membrane sensor and 1.0 9 10-6 M was obtained for carbon paste sensor. The proposed sensors showed very good selectivity toDOMin the presence of a large number of other interfering ions. The analytical application of the developed sensors in the determination of the drug in pharmaceutical formulations such as tablets was investigated. The results obtained are in good agreement with the values obtained by the standard method. The sensors were also applied for the determination ofDOMin real samples such as urine by the standard addition method. |
Description: | J Appl Electrochem (2010) 40:65–71 DOI 10.1007/s10800-009-9975-2 |
URI: | http://dyuthi.cusat.ac.in/purl/4011 |
Files | Size |
---|---|
Novel potentiom ... minationof domperidone.pdf | (282.8Kb) |
Abstract: | A set of six new polystyrene anchored metal complexes have been synthesized by the reaction of the metal salt with the polystyrene anchored Schiff base of vanillin. These complexes were characterized by elemental analyses, Fourier transform infrared spectroscopy, diffuse reflectance studies, thermal studies, and magnetic susceptibility measurements. The elemental analyses suggest a metal : ligand ratio of 1 : 2. The ligand is unidentate and coordinates through the azomethine nitrogen. The Mn(II), Fe(III), Co(II), Ni(II), and Cu(II) complexes are all paramagnetic while Zn(II) is diamagnetic. The Cu(II) complex is assigned a square planar structure, while Zn(II) is assigned a tetrahedral structure and Mn(II), Fe(III), Co(II), and Ni(II) are all assigned octahedral geometry. The thermal analyses were done on the ligand and its complexes to reveal their stability. Further, the application of the Schiff base as a chelating resin in ion removal studies was investigated. The polystyrene anchored Schiff base gave 96% efficiency in the removal of Ni(II) from a 20-ppm solution in 15 min, without any interference from ions such as Mn(II), Co(II), Fe(III), Cu(II), Zn(II), U(VI), Na , K , NH4 , Ca2 , Cl , Br , NO3 , NO2 ,and CH3CO2 . The major advantage is that the removal is achieved without altering the pH. |
URI: | http://dyuthi.cusat.ac.in/purl/514 |
Files | Size |
---|---|
jour appli poly science.pdf | (75.34Kb) |
Abstract: | A new PVC membrane sensor, which is highly selective towards Ni (II) ions, has been developed using a thiophene-derivative Schiff base as the ionophore. The best performance was exhibited by the membrane having the composition percentage ratio of 5:3:61:31 (ionophore:NaTPB:DBP:PVC) (w=w), where NaTPB is the anion excluder, sodium tetraphenylborate and DBP is the plasticizing agent (dibutyl phthalate). The membrane exhibited a good Nernstian response for nickel ions over the concentration range of 1.0 10 1– 5.0 10 6M (limit of detection is 1.8 10 6 M) with a slope of 29.5 1.0mV per decade of activity. It has a fast response time of<20 s and can be used for a period of 4 months with good reproducibility. The sensor is suitable for use in aqueous solutions of a wide pH range of 3.2–7.9. The sensor shows high selectivity to nickel ions over a large number of mono-, bi- and trivalent cations. It has been successfully used as an indicator electrode in the potentiometric titration of nickel ions against EDTA and also for direct determination of nickel content in real samples – wastewater samples from electroplating industries and Indian chocolates. |
URI: | http://dyuthi.cusat.ac.in/purl/512 |
Files | Size |
---|---|
fulltext.pdf | (96.13Kb) |
Abstract: | A new PVC membrane sensor, which is highly selective towards Ni (II) ions, has been developed using a thiophene-derivative Schiff base as the ionophore. The best performance was exhibited by the membrane having the composition percentage ratio of 5:3:61:31 (ionophore:NaTPB:DBP:PVC) (w=w), where NaTPB is the anion excluder, sodium tetraphenylborate and DBP is the plasticizing agent (dibutyl phthalate). The membrane exhibited a good Nernstian response for nickel ions over the concentration range of 1.0 10 1– 5.0 10 6M (limit of detection is 1.8 10 6 M) with a slope of 29.5 1.0mV per decade of activity. It has a fast response time of<20 s and can be used for a period of 4 months with good reproducibility. The sensor is suitable for use in aqueous solutions of a wide pH range of 3.2–7.9. The sensor shows high selectivity to nickel ions over a large number of mono-, bi- and trivalent cations. It has been successfully used as an indicator electrode in the potentiometric titration of nickel ions against EDTA and also for direct determination of nickel content in real samples – wastewater samples from electroplating industries and Indian chocolates. |
URI: | http://dyuthi.cusat.ac.in/purl/515 |
Files | Size |
---|---|
mca paper 06.pdf | (96.5Kb) |
Abstract: | new PVC membrane ion selective electrode which is highly selective towards Ni(II) ions was constructed using a Schiff base containing a binaphthyl moiety as the ionophore. The sensor exhibited a good Nernstian response for nickel ions over the concentration range 1.0 × 10–1 – 5.0 × 10–6 M with a lower limit of detection of 1.3 × 10–6 M. It has a fast response time and can be used for a period of 4 months with a good reproducibility. The sensor is suitable for use in aqueous solutions in a wide pH range of 3.6 – 7.4 and works satisfactorily in the presence of 25% (v/v) methanol or ethanol. The sensor shows high selectivity to nickel ions over a wide variety of cations. It has been successfully used as an indicator electrode in the potentiometric titration of nickel ions against EDTA and also for the direct determination of nickel content in real samples: effluent samples, chocolates and hydrogenated oils. |
URI: | http://dyuthi.cusat.ac.in/purl/516 |
Files | Size |
---|---|
nickel anal.sci..pdf | (72.34Kb) |
Abstract: | PVC supported liquid membrane and carbon paste potentiometric sensors incorporating an Mn(III)-porphyrin complex as a neutral host molecule were developed for the determination of paracetamol. The measurements were carried out in solution at pH 5.5. Under such conditions paracetamol exists as a neutral molecule. The mechanism of molecular recognition between the Mn(III)-porphyrin and paracetamol, leading to potentiometric signal generation, is discussed.The sensitivity and selectivity toward paracetamol of carbon paste and polymeric liquid membrane electrodes incorporating an Mn(III)-porphyrin host were compared. The applicability of these sensors to the direct determination of paracetamol was checked by performing a recovery test in human plasma. |
URI: | http://dyuthi.cusat.ac.in/xmlui/purl/1988 |
Files | Size |
---|---|
PVC Supported Liquid....pdf | (223.7Kb) |
Abstract: | Salicylaldehyde Schiff base of amino-methylated polystyrene has been developed as a novel reagent for the removal of Fe(III) from solutions. The selectivity of the metal ion uptake over a wide range of different concentrations of metal ion, effect of pH, ligand concentration and the influence of other foreign ions were studied. A very good selectivity was achieved for the removal of the ion. It was found that 0.01 g of the ligand was sufficient to achieve about 96% removal of the metal ion in terms of concentration (ppm) from a 30 ppm solution in acidic pH. |
URI: | http://dyuthi.cusat.ac.in/purl/511 |
Files | Size |
---|---|
env.che.lett.published.pdf | (159.9Kb) |
Abstract: | A spectrophotometric method employing 2-hydroxybenzaldiminoglycine (HBIG) is proposed for the determination of chromium(III). The results of the determinations are compared with the standard diphenyl carbazide method. The presently developed method is direct, simple, rapid, selective, sensitive and precise. |
URI: | http://dyuthi.cusat.ac.in/purl/513 |
Files | Size |
---|---|
jour anal chem.pdf | (26.72Kb) |
Abstract: | Two simple and sensitive spectrophotometric methods(A and B) in the visible region have been developed for the determination of cefotaxime sodium (DFTS) in bulk and in dosage forms. Method A is based on the reaction of CFTS with nitrous acid under alkaline conditions to form a stable violet colored chromogen with absorption maximum of 560 nm and method B is based on the reaction of CFTS with1,10-phenanthroline and ferric chloride to form a red colored chromogen with the absorption maximum of 520 mm.The color obeyed Beer’s law in the concentration range of 100-500 µg/ml for method A and 1.6-16 µg/ml for method B, respectively.When pharmaceutical preparations containing CFTS were analysed, the results obtained by the proposed methods are in good agreement with the labeled amounts and are comparable with the results obtained using a UV spectrophotometric method. |
URI: | http://dyuthi.cusat.ac.in/xmlui/purl/1929 |
Files | Size |
---|---|
Spectrophotomet ... Cefotaxime Sodium.....pdf | (222.8Kb) |
Abstract: | A series of nonelectrolytic lanthanide(III) complexes, [ ML 2 Cl 3 ] · 2 H 2 O, where M is lanthanum(III), praseodymium(III), neodymium(III), samarium(III), gadolinium(III), terbium(III), dysprosium(III), and yttrium(III), containing sulfamethoxazole ligand (L) are prepared. The structure and bonding of the ligand are studied by elemental analysis, magnetic susceptibility measurements, IR, 1 H NMR, TG / DTA , X-ray diffraction studies, and electronic spectra of the complexes. The stereochemistry around the metal ions is a monocapped trigonal prism in which four of the coordination sites are occupied by two each from two chelating ligands, sulfonyl oxygen, and nitrogen of the amide group and the remaining three positions are occupied by three chlorines. The ligand and the new complexes were tested in vitro to evaluate their activity against the bacteria Escherichia coli and Staphylococcus aureus. |
URI: | http://dyuthi.cusat.ac.in/xmlui/purl/1992 |
Files | Size |
---|---|
Synthesis and S ... ation of Lanthanide....pdf | (191.2Kb) |
Now showing items 1-19 of 19
Dyuthi Digital Repository Copyright © 2007-2011 Cochin University of Science and Technology. Items in Dyuthi are protected by copyright, with all rights reserved, unless otherwise indicated.